The arithmetic
Heating a gallon of water by one degree Fahrenheit takes about 8.3 BTUs. At one gallon per minute, raising the temperature 55 degrees takes about 27,000 BTUs per hour, or roughly 8 kilowatts. At 1.5 gallons per minute, it is about 12 kilowatts. A 15-amp 120-volt circuit delivers at most 1,800 watts, and a continuous load should stay below about 1,440 watts.
What it means in a shower
With 1.5 kilowatts available, a unit can heat only a trickle to shower temperature, around a quarter of a gallon per minute at that temperature rise. The result is a lukewarm, weak flow. Lower the flow and the temperature rise falls, but showering at a trickle is not what most people want.
What a 120V unit is good for
Small point-of-use units suit jobs where a little warm water is enough.
- A hand sink in a bathroom or workshop far from the main heater.
- A utility sink where a quick rinse is enough.
- Pre-warming water at a single remote faucet.
- Boosting a faucet that is far from the tank in an addition.
What a shower needs
Whole-fixture tankless heaters for showers are either electric units on high-amperage 240-volt circuits or gas units. An electric whole-house unit may need 100 amps or more of dedicated service, which often means an electrical panel upgrade. A gas unit needs gas line capacity and venting, covered in our guide to gas tankless installs. A small tank is often the sensible choice for a single remote bathroom.
| Option | Pros | Cons |
|---|---|---|
| Point-of-use 120V | Cheap, easy install | Cannot run a shower |
| Electric 240V point-of-use | Real shower flow possible | Needs a large dedicated circuit |
| Small electric tank | Simple, stable | Takes floor space, limited volume |
| Whole-house tankless | Continuous hot water | Gas or large electric service required |
Labels that mislead
Some product listings call a small 120-volt unit a shower heater. Read the specifications: the rated flow at your cold water temperature is the number to check. If the listing does not show gallons per minute at a stated temperature rise, be cautious.
Cold incoming water makes it worse
Winter water is colder, so the temperature rise needed is larger, and the same unit delivers even less. A heater that seems fine in summer may fail in January. Ask the manufacturer for the flow rating at the coldest water you will see.
Next steps
If you want hot water at one far bathroom, a short call lets us look at the circuit, the pipe run and the options. See tankless water heater service for what we handle, or water heater installation for tank options.
A worked example
Say your cold water is 50 degrees and you want a 105 degree shower, a 55 degree rise. At 2 gallons per minute you move 120 gallons an hour. Each gallon takes about 8.3 BTU per degree, so 120 gallons times 55 degrees times 8.3 is about 54,800 BTU per hour, or roughly 16 kilowatts. Your outlet offers a tenth of that.
Gas tankless as the alternative
Gas units deliver far more heat from a smaller connection, which is why they are common for whole-home use. They need adequate gas supply, a vent to the outdoors and a condensate drain. In a condo the vent path may be the deciding factor, so ask the association before you plan one.
Low-flow fixtures help
A lower-flow showerhead cuts the heat needed. Dropping from 2.5 to 1.5 gallons per minute reduces the load by 40 percent. It does not make a 120-volt unit workable, but it helps any heater, and it lowers the water bill.
Questions to ask a seller
Ask for the rated flow at your winter water temperature, the circuit size required and whether the unit is approved for shower use. If a seller cannot answer, that is a sign to look elsewhere.